ESIM251/ESIM252 User Manual v.2.0
19. MONITORING STATION
The system can be congured to report events to the monitoring station by transmitting data messages to the monitoring station. The
system connects to the monitoring station when the MS (Monitoring Station) mode is enabled.
Enable/disable
MS mode
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Account is a 4-digit number (By default – 9999) required to identify the alarm system unit by the monitoring station.
Set account
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
ATTENTION: The system will NOT transmit any data to the monitoring station while remote conguration, remote rmware update
or remote listening is in progress. However, during the remote conguration session, rmware update process or remote listening pro-
cess, the data messages will be queued up and transmitted to the monitoring station after the remote conguration session, rmware
update or remote listening process is over.
19.1. Data Messages - Events
The conguration of data messages is based on Ademco Contact ID protocol. The data messages can either be transmitted to the moni-
toring station alone or with duplication by SMS text message to the listed user phone number. For more details on system notications by
SMS text message, please refer to 15. SYSTEM NOTIFICATIONS.
Seq. No. Contact ID® Code Event Description
1 1130 Input alarm Transmitted in case an input is violated.
2 3130 Input restore Transmitted in case an input is restored.
3 1602 Test event Transmitted for system online status verication purposes.
4 3626 Date/time not set Transmitted in case system date & time is not set.
5 1354 GPRS connection loss Transmitted in case the GPRS connection is lost.
Manage data
messages
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
19.2. Communication
The system supports the following communication methods and protocols:
GPRS network – EGR100 and Kronos protocol.
Voice calls (GSM audio channel) – Ademco Contact ID protocol.
Any communication method can be set as primary or backup connection. The user can set up to 5 backup connections in any sequence
order.
Initially, the system communicates via primary connection with the monitoring station. By default, if the initial attempt to transmit data
is unsuccessful, the system will make additional attempts until the data is successfully delivered. If all attempts are unsuccessful, the
system will follow this pattern:
a) The system switches to the backup connection.
b) The system then attempts to transmit data by the backup connection.
c) If the initial attempt is unsuccessful, the system will make additional attempts until the data is successfully delivered. The connection
is considered unsuccessful under the following conditions:
GPRS network – The system has not received the ACK data message from the monitoring station within 40 seconds.
Voice calls:
The system has not received the “handshake” signal from the monitoring station within 40 seconds.
The system has not received the “kisso” signal from the monitoring station within 5 attempts each lasting 1 second.
e) If one of the attempts is successful, the system will transmit all queued up data messages by this connection.