10
3. Additional System Capabilities
3.1 Renaming alarm, restore text and controller names
Manufacturer initially set the following zone and controlled output names:
Zone1, Zone2, Zone3, Zone4, Zone5, OUTPUT1
E. g. if during the alarm Z1 zone was triggered, the system sends SMS message with the text: Zone1
AlarmtextchangesaremadebysendingthefollowingSMSmessage:
E. G. XXXX_Z1:Intrusion though the door;Z2:Fire sensor triggered;
Textscanbechangedallatonceforallzones,severalofthemoronebyone.Maximumtextforonezone
is24characters.Thespaceisequaltoonecharacter.Eachnewtextmustbefollowedbyasemicolon.As
semicolonisusedforseparatingtextsfordierentzones,itcannotbeusedinthemiddleofalarmtexts
itcanonlybeusedattheend.Textscannotbethesameascontrolcommands.
Triggered zone restore text
If you want to be notied by an SMS message when the triggered zone is restored Restore mode must be turned on. The mode is
turned on by sending a particular SMS command. Please refer to chapter 3.9 or conguration program.
ZonerestoretextischangedbysendingthefollowingSMSmesaage:
Controller name can be changed by sending the following SMS message:
Controller name cannot be followed by a semi colon. You cannot change zone names and controller
names at the same time.
E. g. XXXX_C1:PUMP
3.2 Enabling/Disabling Zones
NOTE
Manufacturer set all the zones activated, i. e. in mode ON.
USEFUL INFORMATION
The zones can be enabled/disabled together or separately one by one.
Enabling Zone
Any zone can be enabled by sending the following SMS message:
XXXX_Z1:NewAlarmText;Z2:NewAlarmText;Z3:NewAlarmText;Z4:NewAlarmText;Z5:NewAlarmText;
XXXX_ZR1:NewRestoreText;ZR2:NewRestoreText;ZR3:NewRestoreText;ZR4:NewRestoreT
ext;ZR5:NewRestoreText;
XXXX_C1:NewControllerName
XXXX_Z1:ON;Z2:ON;Z3:ON;Z4:ON;Z5:ON;
ESIM 251
XXXX_Z1:
trespaced;
Z2:
triggered
re
detector;
ESIM 251
XXXX_C1:
PUMP