3.9.2.3 Output ontrol settings by event time
ThischapterdescribesapossibilitytocontrolC1output(relay)usingtimetable(schedule).Itcanbe,forinstance,atomaticturning
on every day at 18:00 and turning o after 5 hours.
The parameters are changed by sending the following SMS message to the system ESIM251:
XXXX–userpassword.ValuestructureisCnVal,whenCniscommandname(2letters),andVal-itsvalue.
Value (CnVal) – table of values
Cn – command
name (2
letters)
Val –
possible
command
meaning.
Command
description
Initial factory
default values
Comments
Setting enabling/
disabling time
WT
h.m
h hour m
minutes
Indicates the time for
enabling or disabling
C1 output in hours
and minutes
E. g. WT18.10 means event start time. It can be
enabling and disabling. It depends on the set
ST value. A period PT must also be indicated,
otherwise relay status will not change. See below.
Setting relay
status, whether
it is enabled or
disabled
ST
1 Relay is enabled
ST1
Relay is
enabled
E. g. ST1 means that when the set time comes the
relay is enabled by WT command.
0 Relay is disabled
E. g. ST0 means that when the set time comes the
relay is disabled by WT command.
Setting the period
of enabling/
disabling
PT
h.m
h hour m
minutes
Indicates the time in
hours and minutes for
which C1 relay status
is changed.
E. g. PT1.20 means that after automatic enabling/
disabling which is indicated in WT command relay
status is changed to opposite for 1 hour and 20
minutes.
Setting
conrmation call
for period start
CS
1
Users are notied
about period start by
a conrmation call
CS1 means that the preset user is informed about
the period start of C1 output enabling or disabling
via short call. The user is set by using UC command.
See below.
0
Users are not notied
about period start by
a conrmation call
СS0
Call is not
made
CS0 means that nobody is informed about period
start by a call.
Setting
conrmation call
for period end
CE
1
Users are notied
about period end by a
conrmation call
CE1 means that the preset user is informed about
the period end of C1 output enabling or disabling
via short call. The user is set by using UC command.
See below.
0
Users are not notied
about period end by a
conrmation call
СE0
Call is not
made
CE0 means that nobody is informed about period
end by a call.
Conrmation call
duration
CT 1; s
The user receives
a conrmation call
when the output is
enabled;
s- call time in seconds
СT12
The rst digit is a command; the last digit refers
to call time in seconds. E. g. СT12 means that if
conrmation call mode is enabled, whether for
period start ot end, the call will be forwarded to
the user when relay is enabled. The system will call
for 2 seconds.
XXXX_SMSEXTRA:OCTE:Value1,Value2,……,ValueN
FOR ADVANCED USERS
All these features can be congured using program “ELDES Conguration Tool“