Eldes ESIM251 User Manual Page 28

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 27
28
Type of control
via call
MS
1,2,3,4,5 and 0
When users
No:1,2,3,4,5 call the
output is enabled.
The rst digit refer to user number. The second
digit refers to command. Therefore to set a
possibility for user NO1 to enable the relay via call
you have to use the command MS10
1,2,3,4,5 and 1
When users
No:1,2,3,4,5 call the
output is disabled.
MS11
The rst digit refer to user number. The second
digit refers to command. Therefore to set a
possibility for user NO1 to disable the relay via call
you have to use the command MS11
1,2,3,4,5 and 2
When users
No:1,2,3,4,5 call
output status is
changed(TOGGLE)
The rst digits refer to user number. The last digit
refers to command. Therefore to set a possibility
for user NO1 to enable the relay by one call and
thendisableitbythenextcallyouhavetosethe
command MS12
Setting relay
impulse
duration
MS
1,2,3,4,5 and
Th.m.s
Setting relay impulse
duration for users
No:1,2,3,4,5. h- hours,
m- minutės, s-
seconds.
E. g. to set the timer for 5 hours 10mins 3seconds
for user NO1 you have to use the command
MS1T5.10.3
This means that when afore mentioned user NO1
control the relay via call the impulse duration is
5hours 10mins and 3seconds and after this period
the relay returns to the previous status.
Example of SMS message conguring C1 output:
This message congures C1 output parameters.
CE1234 meansthatС1outputcanbecontrolledbyusersNO1-NO4(NO5cannotcontrolviacall).
CS123 means that only users NO1, NO2 and NO3 will receive conrmation call.
MS10 means that when user NO1 calls the system he/she enables C1 input, but cannot disable it via call. The user can disable it via
SMS message if he/she knows the password.
MS42meansthatwhenuserNO4callsthesystemhe/shewilleitherenableordisableoutputC1(TOGGLEmodeison).Itdepends
on the relay status before making a call.
MS1T0.0.40 means that when user NO1 call the relay is turned on for 40seconds and then it automatically turns o.
To see the preset values for any command send SMS message with the same format that you use when changing parameters; only
Value structure will have no value. This does not apply to MS and CT commands. When requesting MS and CT parameters MS and
CTmustbefollowedbyonecharacter–usernumber(1,2,3,4or5).:
XXXX–userpassword.ValuestructureisCn,whereCniscommandname(2letters).
E. g. XXXX_SMSEXTRA:COC:CE,CS,MS1,MS3
3.9.2.2 Settings of the output controlled by SMS messages
This chapter describes the ways of informing users when they are trying to enable/disable the relay via SMS messages described in
chapter 3.6. Parameters are changed by sending the following SMS message to system ESIM251:
XXXX–userpassword.ValuestructureisCnVal,whereCniscommandname(2letters),andVal-itsvalue(digitswithoutspacesor
punctuationmarks).
XXXX_SMSEXTRA:COC:CE1234,CS123,MS10,MS42,MS1T0.0.40
XXXX_SMSEXTRA:COC:Value1,Value2,……,ValueN
XXXX_SMSEXTRA:OCS:Value1,Value2,……,ValueN
FOR ADVANCED USERS
All these features can be congured using program “ELDES Conguration Tool“
Page view 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 34 35 36

Comments to this Manuals

No comments