USER MANUAL ELDES ESIM251 V1.0 31
FOR ADVANCED USERS
All these features can be congured using program “ELDES Conguration Tool“
0; s
The user receives
a conrmation call
when the output is
disabled;
s- call time in seconds
СT08
The rst digit is a command; the last digit refers to
call time in seconds.
E. g. СT08 means that if conrmation call mode
is enabled, whether for period start ot end, the
call will be forwarded to the user when relay is
disabled. The system will call for 8 seconds.
Setting the user
who receives
conrmations
about period
start/end
UC 1,2,3,4,5
Sets which user is
notied about period
start/end.
UC1
E. g. UC2 means that all conrmations will be
delivered to user No2.
Only one user can be selected.
Setting
conrmation
SMS message for
period start
SS
1
Users are notied
about period start by
SMS message
SS1 means that the preset user is notied about
period start of enabling/disabling C1 output
by SMS message. The user is set by using UC
command. See below.
0
Users are not notied
about period start by
SMS message
SS0
SS0 means that nobody is informed about period
start by SMS message.
Setting
conrmation
SMS message for
period end
SE
1
Users are notied
about period end by
SMS message
SE1 means that the user is also notied about relay
disabling by SMS message.
0
Users are not notied
about period end by
SMS message
SE0
SE0 means that nobody is informed about period
end by SMS message.
Example of SMS message conguring C1 output ways of information by preset schedule:
This message congures C1 output parameters using a schedule.
WT20.15 means that relay enablig time is set for 20:15 every day.
ST1 means the user set the relay to turn on on that time.
PT8.5 means that the relay is enabled and is on for 8 hours and 5 minutes, and after that it turns o and turns on again at 20:15 the
following day etc.
UC2 meansthatinformationaboutenabling/disablingissenttouser’sNo2telephone.
CS1 means that the user is notied about relay enabling by a callback; the duration of the call is set by parameter CT13. CT13 means
that the system calls for 3 seconds.
CT06 means that when the relay turns o after 8 hours and 5 minutes the user is notied by a call again, but call duration is 6
seconds.
SE1 means that the user is also notied about relay enabling by SMS message.
To see the preset values for any command send SMS message with the same format that you use when changing parameters; only
Value structure will have no value:
XXXX–userpassword.ValuestructureisCn,whereCniscommandname(2letters).
E. g. XXXX_SMSEXTRA:OCTE:CB,CT,SB
XXXX_SMSEXTRA:OCTE:WT20.15,ST1,PT8.0,UC2,CS1,CT13,CT06,SE1
XXXX_SMSEXTRA:OCTE:Value1,Value2,……,ValueN
Comments to this Manuals