Eldes ESIM251 User Manual Page 23

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 22
USER MANUAL ELDES ESIM251 V1.0 23
FOR ADVANCED USERS
All these features can be congured using program “ELDES Conguration Tool“
As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the rst successful
delivery of the SMS message, it is necessary to remove users NO1 and NO3 and disable alarm calls for all users. It is also necessary to
enableimpulsecountingmodeforESIM251inputZ3andsetthenumberofexpectedimpulses.
a)FirstofallasignalindicatingPUMPtriggeringisconnectedtoESIM251inputZ3.
b) ThefollowingcongurationSMSmessagemustbesenttoESIM251system:
where SC13 means that alarm SMS message sending is disabled for users NO1, NO3 after Z3 zone activation.
CC123 means that alarm calls are disabled for users NO1, NO2 and NO3 after Z3 zone activation.
We make an assumption that users NO4-NO5 were not entered to the system at all.
IE1 enables impulse counting mode for zone Z3. IC10 means that the alarm is given to Z3 input after 10 impulses are transmitted.
Task No2:
Conguringthesystemsothattheoperatingpersonnelmember(NO2)receivesSMSmessageifthepumpwastriggeredfor10
times.
XXXX_SMSEXTRA:Z3:SC13,CC123,IE1,IC10
Worker
NO1
Worker
NO2
Worker
NO3
Pump
Gas boiler
ESIM151
Automatic
system
Alarm
SMS
Page view 22