FOR ADVANCED USERS
All these features can be congured using program “ELDES Conguration Tool“
E. g. 1
TheuserwantstoconnectESIM251systemtoanexistingalarminabuildingwhereenterpriseAandandenterpriseBwork.Both
enterprisesusethesamealarmsystemthathastwozones.Thealarmsystemhas5programmableoutputs(PGM).
Task NO3:
ConguringthesystemsothattheintrusiontoenterpriseApremisesisreportedtothejanitor(NO3)andenterpriseAemployee
(NO4)bySMSmessagesandcalls.EnterpriseAemployee(NO4)wantstoreceiveacallonlyinthecaseifthejanitor(NO3)doesnot
answerthecall,isoutofnetworkcoverageoratthattimethejanitor’stelephonelineisengaged.
As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the rst successful
deliveryoftheSMSmessage,itisnecessarytoenablemandatorySMSmessagedelivery(seemoreinchapter3.7)andtoremove
the users who should not receive alarm messages. Besides, as per factory default settings, calling feature in the case of alarm is also
enabledforallusersthereforecallfunctionmustbedisabledforallusersexceptusersNO3andNO4.Asperfactorydefaultsettings
in the case of alarm the system rings until the rst answered call, therefore in this case nothing should be congured.
a)FirstofallsecuritycentralunitmustbeprogrammedinthewaysothatwhensecuritysensorsofenterpriseAaretriggered
the signal is transmitted to security central unit output PGM4.
b)PGM4isconnectedtoESIM251inputZ4
c) ThefollowingcongurationSMSmessagesmustbesenttoESIM251system:
where SMSALL enables mandatory SMS message delivery feature for all users.
Where SC125 means that alarm SMS message delivery feature is disabled for users NO1, NO2 and NO5 after Z4 zone is triggered.
CC125 means that alarm calls are disabled for users NO1, NO2 and NO5 after Z4 zone is triggered.
XXXX_SMSALL:ON
XXXX_SMSEXTRA:Z4:SC125,CC125
Alarm
SMS/Calls
Alarm
SMS/Calls
PGM4
Enterprise A Enterprise B
ESIM151
PIR
PIR
Director A
NO1
Director B
NO2
Worker A
NO4
Worker B
NO5
Janitor
NO3
Janitor
Alarm system
GATES