Eldes ESIM251 User Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
USER MANUAL ELDES ESIM251 V1.0 7
1.6 System Installation
The system can be installed only in a metal or non-ammable plastic enclosure. If the metal enclosure and transformer is used it
isnecessarytogroundtheenclosureusingyellow/greencolourcable.Fortheconnectionof230Vtransformeruse3x0.75mm2
1 thread double isolated cable. The primary circuit of the transformer must be connected through 0.5A fuse. 230V power supply
cables cannot be grouped with low voltage cable group. For the connection of power supply and output connectors use 1 thread
2x0.75mm2cable.Fortheconnectionofinput/outputconnectorsuse0.50mm21threadcable.
1. Fastenthesystemintheboxusingfasteningholders.
2. PlaceSIMcardintheholderbutmakesurethatSIMcardPINcodeisdisabled.(PINcodecanbedisabledbyputtingSIMcard
intomobilephoneandfollowingpropermenus).SIMcardshouldnothaveanyremainingSMSmessages.
3. Connectthecircuitasshowning.No2.Powersupplycablesareconnectedlast).WhenconnectingESIM251toalarmsystem
power supply, usually the security system AUX output is used.
4. WhenACpowersupply(groundtransformator)isusedconnectaccordingtocircuitno.3.Inthiscaseyoudonotneedto
connect any other power supplies.
5. The system will start in less than a minute. LED2 indicator should be blinking or be ON indicating connection to GSM.
Picture3 AC power supply connection circuit
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 35 36

Comments to this Manuals

No comments