FOR ADVANCED USERS
All these features can be congured using program “ELDES Conguration Tool“
Task NO4:
ConguringthesystemsothattheintrusiontoenterpriseBpremisesisreportedtothejanitor(NO3)andenterpriseBemployee
(NO5)bySMSmessagesandcalls,andthedirectorofenterpriseB(NO2)receivesSMSmessageonly.EnterpriseBemployee(NO5)
mustreceivethephonecalleveninthecasewhenthejanitor(NR3)answersthecall.
As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the rst successful
deliveryoftheSMSmessage,itisnecessarytoenablemandatorySMSmessagedelivery(seemoreinchapter3.7)andtoremove
the users who should not receive alarm messages. Besides, as per factory default settings, calling feature in the case of alarm is also
enabled for all users therefore call function must be disabled for users NO1, NO2 and NO4, and left enabled for users NO3 and NO5.
Also,itisnecessarytoenablemandatorycallingfeatureforallpresetusers(seemoreinchapter3.8).
a) Firstofallsecuritycentralunitmustbeprogrammedinthewaysothatwhensecuritysensorsaretriggeredthesignalmust
be transmitted to security central unit output PGM5.
b)PGMisconnectedtoESIM251inputZ5
c) ThefollowingthreecongurationSMSmessagesmustbesenttoESIM251system:
where SMSALL enables mandatory SMS message delivery feature for all users.
where CALLALL enables mandatory calling feature for all users.
where SC14 means that alarm SMS message sending feature is disabled for users NO1 and NO4 after Z5 zone is triggered.
CC124 means that alarm calls are disabled for users NO1, NO2 and NO4 after Z5 zone is triggered.
XXXX_SMSALL:ON
XXXX_CALLALL:ON
XXXX_SMSEXTRA:Z5:SC14,CC124
Alarm
SMS/Calls
Alarm
SMS/Calls
Alarm
SMS
PGM5
PIR
PIR
ESIM151
Enterprise A Enterprise B
Director A
NO1
Director B
NO2
Worker A
NO4
Worker B
NO5
Janitor
NO3
Janitor
Alarm system
GATES
Page view 16